Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Arq. bras. med. vet. zootec. (Online) ; 69(5): 1191-1197, set.-out. 2017. tab, graf
Article in Portuguese | LILACS, VETINDEX | ID: biblio-877364

ABSTRACT

Aparelhos de automação, cujo uso está estabelecido na hematologia dos animais domésticos, ainda não são empregados rotineiramente em felídeos selvagens. Esse estudo objetivou avaliar a técnica automatizada na contagem de células sanguíneas de jaguatiricas (Leopardus pardalis), comparando-a com a técnica manual. Foram coletadas amostras sanguíneas de oito jaguatiricas, que se submeteram à contagem de eritrócitos, leucócitos, plaquetas e à determinação do volume globular pelo método manual padrão e por meio do aparelho BC - 2800 VET® com a configuração para gatos domésticos. Os resultados foram avaliados por meio do teste t para dados pareados, e as técnicas submetidas à análise de correlação de Pearson. A técnica automatizada demonstrou resultados estatisticamente semelhantes para eritrócitos e leucócitos. Apenas para volume globular houve diferença significativa entre as técnicas manual e automatizada, mas a correlação foi alta. Apesar de não haver diferença significativa entre as técnicas para plaquetas, a correlação foi baixa. Conclui-se que o aparelho BC - 2800 VET® com a configuração para gatos domésticos é uma técnica confiável na realização do eritrograma e do leucograma para jaguatiricas. Para a determinação do parâmetro volume globular, o aparelho pode ser utilizado, desde que se faça a correção. Para a contagem de plaquetas, a técnica manual é recomendada.(AU)


Automated equipment, whose use is established in hematology of domestic animals, is not yet routinely used in blood cells count of wildlife, due to lack of studies that validate its use. The purpose of this study was to evaluate the automated technique for blood cells count of ocelots (Leopardus pardalis), comparing it with the manual technique. Blood samples were collected from eight ocelots, which were submitted to counting of erythrocytes, leukocytes, platelets and packed cell volume by the standard manual method and by the device VET ® 2800 BC with the configuration for domestic cats. The results were evaluated using the t test for paired data and the techniques submitted to Pearson correlation. The automated technique showed statistically similar results to erythrocytes and leukocytes. Significant difference was found only for packed cell volume between the manual and automated techniques, but the correlation was high. Although there was no significant difference between the techniques for platelets, the correlation was low. We concluded that the 2800 BC VET ® device with the configuration for domestic cats is a reliable technique in performing the erythrocyte and leukocyte counts for ocelots. The device may be used to determine packed cell volume, provided the correction is made. The manual technique is recommended for the platelet count.(AU)


Subject(s)
Animals , Erythrocyte Count , Felidae/blood , Hematocrit/veterinary , Hematologic Tests/methods , Hematologic Tests/veterinary , Leukocyte Count
2.
Arq. bras. med. vet. zootec. (Online) ; 69(4): 889-895, jul.-ago. 2017. ilus, tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-876680

ABSTRACT

O principal sistema de grupos sanguíneos reconhecido para gatos é o AB. Os felinos apresentam anticorpos naturais contra o antígeno do tipo sanguíneo a que não pertencem, o que torna os testes de compatibilidade e as tipagens sanguíneas importantes na prevenção de reações transfusionais. O objetivo deste estudo foi realizar a tipagem sanguínea de oito gatos-mouriscos (Puma yagouaroundi), oito jaguatiricas (Leopardus pardalis), sete gatos-palheiros (Leopardus colocolo), sete gatos domésticos (Felis catus) da raça Persa e oito gatos domésticos sem raça definida (SRD), bem como realizar testes de compatibilidade entre os tipos sanguíneos iguais das diferentes espécies, para avaliar a possibilidade de transfusões interespecíficas. A técnica empregada para a tipagem foi a hemaglutinação em tubos de ensaio. A ocorrência do tipo sanguíneo tipo A foi de 100% entre as jaguatiricas, os gatos-palheiros e os gatos Persas e de 85,72% entre os gatos SRD. A ocorrência do tipo B foi de 100% nos gatos-mouriscos e de 14,28% nos gatos SRD. Considerando os testes de compatibilidade sanguínea, 87,5% (n=4) das jaguatiricas foram incompatíveis com os gatos domésticos, 100% (n= 6) dos gatos-palheiros foram compatíveis com os gatos domésticos e 100% (n= 4) dos gatos-mouriscos foram incompatíveis com os gatos domésticos do tipo B.(AU)


The blood group system recognized for cats is AB. Antibodies against other blood types occur naturally in cats, which makes the compatibility tests and blood typing important for preventing transfusion reactions. Wild felids need blood transfusions in cases of diseases and when run over on highways. The aim of this study was to perform blood typing of eight jaguarundies (Puma yagouaroundi), eight ocelots (Leopardus pardalis), seven pampas cats (Leopardus colocolo), seven domestic cats (Felis catus) of Persian breed and eight non-pedigree domestic cats (Felis catus), and test compatibility among the different species with the same blood types, to evaluate the possibility of performing interspecific blood transfusions. We conducted the study from August to December. We used haemagglutination in test tubes for typing. The occurrence of blood type A was 100% among ocelots, pampas cats and domestic cats of Persian breed, while non-pedigree domestic cats showed 85.72%. The occurrence of type B was 100% for jaguarundis and 14.28% for non-pedigree domestic cats. Regarding blood compatibility tests, 87.5% (n= 4) of the ocelots were incompatible with domestic cats; 100% (n=6) of the pampas cats were compatible with domestic cats, while 100% (n=4) of the jaguarundis were incompatible with type B domestic cats.(AU)


Subject(s)
Animals , Cats , Blood Group Antigens , Blood Grouping and Crossmatching/veterinary , Felidae/blood , Puma/blood , Animals, Domestic/blood , Animals, Wild/blood , Blood Group Incompatibility/veterinary , Blood Transfusion/veterinary , Hemagglutination Tests/veterinary
3.
Arq. bras. med. vet. zootec ; 69(1): 75-84, jan.-fev. 2017. ilus, tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-834106

ABSTRACT

RBC count plays an important role in animal diagnosis. Despite the many technologies available in different automated hematology analyzers, when it comes to the blood of wild animals it is still difficult to find an easy and affordable solution for multiple species. This study aims to evaluate the proposed automatic red blood cell counter. Blood samples (1 ocelot - Leopardus pardalis, 1 monkey - Cebus apella, 1 coati - Nasua nasua, 62 dogs - Canis familiaris, and 5 horses - Equus caballus) were analyzed using three methods: 1-manual count, 2-automatic count by image, and 3-semi-automatic count by image; blood from dogs and horses were also analyzed by a fourth method: 4-automatic count by impedance. The counts in methods 2 and 3 were produced by the proposed red blood cell counter. Results were compared using Pearson's correlation and plots with different methods as the criterion standard. RBC counts in methods 1, 2, and 3 correlated very well with those in the method 4 (r ≥ 0.94). RBC counts produced by method 2 were highly correlated with method 3 (r = 0.998). The results indicate that the proposed method can be used as an automatic or semi-automatic counting method in clinics that are currently using the manual method for RBC assessment.(AU)


A contagem de células vermelhas do sangue desempenha um papel importante no diagnóstico de animais. Apesar da existência de muitas tecnologias em diferentes contadores automatizados para análise de sangue, quando se trata do sangue de animais silvestres ainda é difícil encontrar uma solução simples e econômica para múltiplas espécies. O objetivo deste estudo é avaliar o contador de células vermelhas proposto. Amostras de sangue (uma jaguatirica - Leopardus pardalis, um macaco - Cebus apella, um quati - Nasua nasua, 62 cães - Canis familiaris e cinco cavalos - Equus caballus) foram analisadas por três métodos: 1 - contagem manual, 2 - contagem automática por imagem e 3 - contagem semiautomática por imagem; as amostras de cães e cavalos foram analisadas por um quarto método: 4 - contagem automática por impedância. As contagens dos métodos 2 e 3 foram obtidas usando-se o contador de células vermelhas proposto. Os resultados foram comparados por meio da correlação de Pearson e gráficos com diferentes métodos como valor de referência. As contagens dos métodos 1, 2 e 3 se correlacionaram muito bem com as contagens do método 4 (r ≥ 0.94). As contagens produzidas pelo método 2 apresentaram alta correlação com o método 3 (r = 0.998). Os resultados indicam que o contador proposto pode ser usado como um método de contagem automática ou semiautomática em clínicas que usam o método manual para contagem de células vermelhas do sangue de animais.(AU)


Subject(s)
Animals , Dogs , Animals, Domestic/blood , Animals, Wild/blood , Erythrocyte Count/methods , Erythrocyte Count/veterinary , Cebus/blood , Dogs/blood , Felidae/blood , Procyonidae/blood
SELECTION OF CITATIONS
SEARCH DETAIL